  • Jean-Louis Schricke

    Hi,

    What is the procedure for displaying a specific page of a PDF document within a Manual Inspection sequence ?

    Where the PDF document has to be saved  :

    > on the cloud ?

    > on a local network ?

    > on the PC using Operator mode in a web browser ?

    0
    Comment actions Permalink
  • Henrik S. Amundsen

     

    Hi Jean-Louis,

    Currently we support storage/access of Manual Inspection media files to a web location where anonymous access is allowed.

     

    As of version 2016.2 we also support UNC locations (where the UNC path must be accessible from the WATS server), as well as locations which are password protected. In the Sequence Designer, credentials must be defined in the sequence/step where you have set the “MediaUrl” property referring to the password protected location.

     

    If you want to display a PDF, you can set the “MediaUrl” property with an web address to the PDF file. This can be set on any sequence/step, but usually this is set in the “root” sequence if only one PDF file is displayed during the test.  The “MediaUrl” is inheritable, so that any sub sequence or step also uses the same URL - but can refer to different pages/sentences in the PDF. More information on this topic is available in our In-App Help documentation: WATS Control Panel -> Manual Inspection Manager -> Sequence Designer.

    0
    Comment actions Permalink
  • Kevin Fuhrer

    Hi,
    Does the barcode identifiers also work by scanning the sub-unit within the sequence of a manual inspection?
    Because our qr codes containing always several information and not the serial number only.
    Thanks

    0
    Comment actions Permalink
  • Ola Lund Reppe

    Hi Kevin, provided that the barcode scanner is set up correctly, yes.

    First you need to configure the scanner in the OI configuration: https://support.virinco.com/hc/en-us/articles/13991633116060-Configuring-your-barcode-scanners-in-WATS

    Then set up barcode identifiers for your different barcode formats. These include information on what part of the barcode is SN, PN, REV, BATCH or Process.

    https://support.virinco.com/hc/en-us/articles/360017446159-Extract-serial-number-when-scanning-with-barcode-identifiers

     

    0
    Comment actions Permalink
  • Kevin Fuhrer

    Dear Ola
    Many thanks for this fast reply and suggested solution.
    I'll have a look into the barcode scanner settings.

    0
    Comment actions Permalink