--Header-Start-- SerialNumber 61616161 PartNumber 100200 Revision A OperationTypeName SW Debug UUTStatus Failed ErrorCode 0 ErrorMessage ExecutionTime 10 BatchSerialNumber B888 StartDateTime 2016-04-11T12:48:58 StationName VIC-WS-DD OperatorName Dubbe dutt SoftwareName c:\test.seq SoftwareVersion 1.0.0.0 Subunit Main board Partno 1 SN 6654433 Rev 1 Subunit Controller Card Partno 2 SN 5555 Rev B uCSwVer 1.0 --Step-Data-Start-- StepType StepName MeasureName Value LowLimit HighLimit CompOperator Unit StepStatus StepExecutionTime StepReportText StepErrorCode StepErrorMessage CausedSequenceFailure SequenceCall SubSeq1 Passed 10 This is a seq call report text NumericLimitTest test1.1 7 7 10 GELE Volt Passed 5 This is a test step report text NumericLimitTest test1.2 8 7 10 GELE Volt Passed 5 EndSequenceCall SequenceCall SubSeq2 Passed 10 NumericLimitTest test2.2 meas1 9 7 10 GELE Volt Passed 5 NumericLimitTest test2.2 meas2 10 7 10 GELE Volt Passed 5 EndSequenceCall NumericLimitTest Test3 meas1 8 10 EQ Volt Failed 1 True NumericLimitTest meas2 6 5 EQ Volt Failed NumericLimitTest meas3 10 10 EQ Volt Passed PassFailTest test4 TRUE Passed 2 PassFailTest test5 meas1 FALSE Failed 3 PassFailTest meas2 TRUE Passed PassFailTest meas3 TRUE Passed PassFailTest meas4 FALSE Failed StringValueTest Test6 The quick brown fox jump over lazy dogs the quick brown fox jump over lazy dogs EQ Failed 4 ActionStep Action Passed 5 SequenceCall SubSeq3 Passed 20 Test Multiple with same stepName NumericLimitTest SameStepName meas1 7 7 10 GELE Volt Passed 5 This is a test step report text NumericLimitTest SameStepName meas2 8 7 10 GELE Volt Passed 5 EndSequenceCall --Step-Data-End-- UUTStatus Failed -- UUT-End--